Search results for "Observational error"
showing 10 items of 40 documents
Anticipating the impact of pitfalls in kinetic biodegradation parameter estimation from substrate depletion curves of organic pollutants
2019
[EN] Accurate and reliable estimation of kinetic parameters of pollutant biodegradation processes is essential for environmental and health risk assessment. Common biodegradation models proposed in the literature, such as the nonlinear Monod equation and its simplified versions (e.g. Michaelis-Menten-like and first-order equations), are problematic in terms of accuracy of kinetic parameters due to the parameter correlation. However, a comparison between these models in terms of accuracy and reliability, related to data imprecision, has not been performed in the literature. This task is necessary, mainly because the model selection cannot be straightforward, as shown in this work. To facilit…
Colour patch size and measurement error using reflectance spectrophotometry
2017
1 - Over the past twenty years, portable and relatively affordable spectrophotometers have greatly advanced the study of animal coloration. However, the small size of many colour patches poses methodological challenges that have not, to date, been assessed in the literature. Here, we tackle this issue for a reflectance spectrophotometry set-up widely used in ecology and evolution (the beam method). 2 - We reviewed the literature on animal coloration reporting the use of reflectance spectrophotometry to explore how the minimum measurable size of a colour patch is determined. We then used coloured plastic sheets to create artificial colour patches, and quantify the relationship between colour…
Event-triggered robust adaptive control for discrete time uncertain systems with unmodelled dynamics and disturbances
2019
In practice, modelling errors caused by high-order unmodelled dynamics and external disturbances are unavoidable. How to ensure the robustness of an adaptive controller with respect to such modelling errors is always a critical concern. In this study, the authors consider the design of event-triggered robust adaptive control for a class of discrete-time uncertain systems which involve such modelling errors and also are allowed to be non-minimum phase. Unlike some existing event-triggered control schemes, the developed controllers do not require that the measurement errors meet the corresponding input-to-state stable condition. Global stability of the closed-loop system which means that all …
Estimation of Location and Activation Time of Purkinje Myocardial Junctions from Sparse and Noisy Endocardial Electrical Samples
2017
The activation of the myocardial muscle is triggered by Purkinje-myocardial junctions (PMJs), which are the terminal sites of the specialised cardiac conduction system (CCS). Obtaining the location of the PMJs and other sources of endocardial ectopic activity would be desirable for building computer models of cardiac electrophysiology and planning ablation interventions. We present a method to estimate the location and activation times of endocardial electrical sources in a 3D model of the ventricles. The algorithm requires a set of discrete electrical samples on the endocardium, which can include errors in location and activation time. The estimated sources are properly placed with a locat…
Determination of Bolton tooth-size ratios by digitization, and comparison with the traditional method.
2005
The Bolton Index is one of the most useful calculations for precise orthodontic diagnosis as it shows if there is a correct ratio between dental proportions. However, at times, this calculation is not applied because it is a long and time-consuming procedure compared with digital methods. A new digital method for measuring tooth sizes and for calculating the Anterior (ABI) and the Overall (OBI) Bolton Index was tested on 100 sets of study dental casts of the permanent dentition in a Spanish sample and compared with the traditional method. The reproducibility of this digital method versus the traditional one was analysed to determine intra- and inter-examiner measurement errors by calculatin…
Dynamic angular three-dimensional measurement of multisegmental thoracolumbar motion in vivo.
2008
Study design Method validation and in vivo motion segment study. Objective To determine in healthy subjects in vivo intervertebral segmental kinematics and coupled motion behavior in all 3 planes simultaneously for 3 segments and to evaluate whether these results differ from those in the normal population according to the literature. Summary of background data Few studies have provided a direct invasive approach to investigate segmental kinematics in vivo. Dynamic recordings of 3-dimensional segmental motion patterns of adjacent segments have rarely been reported. To date, no studies have examined the 3-dimensional segmental movements of the thoracolumbar junction in vivo in detail. Methods…
Design Issues and Sample Size when Exposure Measurement is Inaccurate
2001
AbstractMeasurement error often leads to biased estimates and incorrect tests in epidemiological studies. These problems can be corrected by design modifications which allow for refined statistical models, or in some situations by adjusted sample sizes to compensate a power reduction. The design options are mainly an additional replication or internal validation study. Sample size calculations for these designs are more complex, since usually there is no unique design solution to obtain a prespecified power. Thus, additionally to a power requirement, an optimal design should also fulfill the criteria of minimizing overall costs. In this review corresponding strategies and formulae are descr…
Balloon-borne match measurements of midlatitude cirrus clouds
2014
Observations of high supersaturations with respect to ice inside cirrus clouds with high ice water content (> 0.01 g kg−1) and high crystal number densities (> 1 cm−3) are challenging our understanding of cloud microphysics and of climate feedback processes in the upper troposphere. However, single measurements of a cloudy air mass provide only a snapshot from which the persistence of ice supersaturation cannot be judged. We introduce here the "cirrus match technique" to obtain information about the evolution of clouds and their saturation ratio. The aim of these coordinated balloon soundings is to analyze the same air mass twice. To this end the standard radiosonde equipment is complemente…
Robust interpretive optimisation in high-performance liquid chromatography considering uncertainties in peak position.
2005
In the context of interpretive chromatographic optimisation, robustness is usually calculated by introducing deliberated shifts in the nominal optimal conditions and evaluating their effects on the monitored objective function, mimicking thus the experimental procedures used in method validation. However, such strategy ignores a major source of error: the uncertainties associated to the modelling step, that may give rise to deceiving results when conditions that were expected to yield baseline separation are reproduced in the chromatograph. Two approaches, based on the peak purity concept, are here proposed to evaluate the robustness of the objective function under the perspective of measur…
Repeatability of in vitro power profile measurements for multifocal contact lenses
2015
Abstract Purpose To evaluate the repeatability of an optical device (NIMO TR1504, Lambda-X, Belgium) for measuring multifocal contact lens power profiles. Methods The NIMO TR1504 was used to measure power profiles 30 times for each of 10 different contact lenses from 4 major companies. All contact lenses were labelled as −3 D for distance vision; half were for high addition and half for low addition. The optical zone in all measurements was set to 3-mm radius. For each lens, the median power profile and the residuals of the 30 measurements were calculated. The 95% confidence bands and two indices that summarize measurement errors were calculated: the repeatability limit and an index of repe…